Speedy Reagent

E-mail Print



Buy 2 tins and SAVE £10.00

Speedy Reagent  - Calcium CarbideSpeedy Reagent 

This 600g tin of Calcium Reagent is for use with the Speedy range of moisture measurement pressure vessels.
 
The calcium carbide reagent used with the Speedy tester is a hazardous product that must be handled with care by the user and with consideration for the environment.

This 600g tin of Calcium Reagent is for use with the Speed range of moisture measurement pressure vessels.

The calcium carbide reagent used with the Speedy tester is a hazardous product that must be handled with care by the user and with consideration for the environment.

Users of the Speedy must be familiar with the Speedy Moisture Test Procedure detailed in this manual.

Users must also follow calcium carbide transportation, storage, handling and disposal guidelines in accordance with local regulations and/or the calcium carbide Material Safety Data Sheet (MSDS). Users should be familiar with the hazard identification, first aid measures, fire-fighting measures, accidental release measures, personal protection measures, physical and chemical properties, stability and reactivity, toxicological information, and ecological information as given in the MSDS

NOTE!
Unopened Tins have a foil seal and screw cap, which means shelf life is virtually unlimited, however, once opened the Calcium Carbide does absorb moisture and oxygen and if used/opened regularly can affect the moisture readings.

For Court work and critical work it is advised to only use NEW tins at all times.

General
Molecular formula: CaC2
CAS No: 75-20-7

Physical data
Appearance: grey or black solid with a garlic-like odour
Melting point: 2300 C
Vapour density: 2.2 (air = 1)
Density (g cm-3): 2.22
Water solubility: decomposes

Stability
Reacts violently with water liberating highly flammable gas (acetylene). Do not use water if this material is involved in a fire.

The equation for Calcium Carbides reaction with water is
CaC2 + 2 H2O → C2H2 + Ca(OH)2
Therefore, 1 gram of CaC2 gives 349ml of acetylene.

Incompatible with moisture, water, strong oxidizing agents, alcohols, hydrogen chloride, magnesium.

Toxicology
Harmful if inhaled, swallowed and in contact with skin. Contact with skin may cause severe irritation or burns

Risk phrases
R15 Contact with water liberates extremely flammable gases.
R20 Harmful by inhalation.
R21 Harmful in contact with skin.
R22 Harmful if swallowed.
R38 Irritating to skin.

Personal protection
Safety glasses, good ventilation. Do not use near water.

The Six Step Moisture Test Procedure
1. Weigh sample
2. Place in speedy
3. Add Reagent
4. Seal speedy
5. Shake speedy
6. Take Reading

Please Note! special delivery conditions apply to this product.

To order a Protimeter Speedy Moisture Meter for use with this product

To order a GANN Chemical Hygrometer for use with this product

Speedy Meter pdf

 

Special Carriage conditions apply for this item £19.99 to UK Mainland 

 

 

 

Bookmark


Newsflash

Leica Builder R100M/R200M Series
£4,200.00
reduced to



Leica Builder Total Stations





Leica Builder R100M/R200M SeriesLeica Builder R100M/R200M Series Total Stations

The digital construction plan
Advantages of the Builder RM

* Receiving and transmitting measured or layout data via digital files increases processing efficiency
* Read and write errors are eliminated
* Data is saved and managed on a PC
* Designs can be implemented directly from the planning stage
* optionally, 3rd party software can operate Builder RM remotely using the interface
 

 

 

Read more...